Time-coordinated Non-arcing Breaking Operation of Reed Switches for Higher Current

机译:用于更高电流的簧片开关的时间协调的非电弧驱动操作

获取原文
获取外文期刊封面目录资料

摘要

At the 50th IEEE Holm conference, we proposed a method for suppressing arc ignition in mechanical contact devices using a transient current switch and a capacitor. We applied the method to conventional reed switches. For the electric circuit analysis, we clarified the momentary voltage-current characteristics at the reed switch breaking operation by FEM analysis. We were able to estimate the non-arc ignition breaking condition using SPICE simulation. It was experimentally confirmed with the capacitor of 9.4 μF for 24V/15A breaking operation.
机译:在第50届IEEE Holm会议上,我们提出了一种用于使用瞬态电流开关和电容器抑制机械接触装置中的电弧点火的方法。我们将该方法应用于传统的簧片交换机。对于电路分析,我们通过有限元分析阐明了簧片开关断裂操作的瞬时电压 - 电流特性。我们能够使用Spice仿真来估计非电弧点火断裂条件。通过9.4μF的电容器进行实验证实24V / 15A断裂操作。