摘要

VI time responses of a conventional electromagnetic relay during breaking contact operations were measured. In a conventional switching circuit, unstable contact resistance, irregular bouncing, and poor reproducibility were confirmed. Using a transient current switch circuit and two sharpened contact electrodes, bouncing during a breaking operation was suppressed, and unstable contact resistance changes and reproducibility of breaking operation were also improved.
机译:测量了常规电磁继电器在断开接触操作过程中的VI时间响应。在常规的开关电路中,证实了不稳定的接触电阻,不规则的弹跳和较差的再现性。使用瞬态电流开关电路和两个尖锐的接触电极,可以抑制断开操作期间的跳动,并且还改善了不稳定的接触电阻变化和断开操作的可重复性。