Firearms noise and hearing conservation: hearing protection fit testing, noise assessment and hearing surveillance

机译:枪支的噪音和听力保护:听力保护适合性测试,噪音评估和听力监测

获取原文

摘要

Background. Noise induced hearing loss (NIHL) continues to be a prevalent problem in Military Service. Purpose. To assess the 'SureFire' earplug, a Hearing Protective Device (HPD), within the context of a hearing conservation programme. Methods. The Sperian 'VeriPro' system was used to test the HPD attenuation. Otoacoustic emissions (OAE) base-line testing assessed base-line status of hearing. Noise exposure during test firing was measured using a B&K precision noise level meter, and a post firing OAE test was carried out to measure any deterioration in hearing due to excess noise exposure. Results. There was a 'between ears' difference in HPD fitting, with better attenuation in right ears. The HPDs were rated to reduce the noise by at least 15 dB in 84% of those exposed. In practice 84% of individuals would have achieved attenuation of between 8.4 and 23.6 dBA. The noise levels during the practice averaged 110 dBA, the actual exposure being 94 dBA, with 84% receiving between 86.4 and 101.6 dBA The OAE testing did not show any significant before and after differences. Discussion. Some individuals achieved good HPD fit, some quite poor. The average noise levels received were excessive, but the daily noise dose would have been within acceptable limits because of the short duration of exposure. This may explain the non-significant differences in OAEs. We recommend that individuals should only use HPDs which are 'fit proven'. Additional testing under more typical conditions with a larger group is required, but OAEs show promise as a practical monitoring tool.
机译:背景。噪声诱发的听力损失(NIHL)仍然是兵役中普遍存在的问题。目的。在听力保护计划的范围内评估“ SureFire”耳塞,即一种听力保护装置(HPD)。方法。 Sperian的“ VeriPro”系统用于测试HPD衰减。耳声发射(OAE)基准测试评估了听力的基准状态。使用B&K精密噪声电平计测量在测试发射过程中的噪声暴露,并执行发射后OAE测试以测量由于过度噪声暴露而导致的听力下降。结果。 HPD贴合度有“耳间”差异,右耳衰减更好。 HPD被评定为在84%的暴露环境中可将噪声降低至少15 dB。在实践中,84%的个人将实现8.4至23.6 dBA的衰减。在实践中,噪声水平平均为110 dBA,实际暴露为94 dBA,其中84%的噪声水平介于86.4和101.6 dBA之间。OAE测试前后的差异没有显着性。讨论。一些人达到了良好的HPD适应度,有些则很差。收到的平均噪音水平过高,但由于暴露时间短,因此每日噪音剂量应在可接受的范围内。这可以解释OAE的非显着差异。我们建议个人仅应使用“适合证明”的HPD。需要在更大组的更典型条件下进行附加测试,但是OAE有望作为一种实用的监视工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号