This work aims at predicting the installed structure-borne sound power of a reference source, using approximated expressions based on equivalent quantities. The installed power level is calculated from the source equivalent free velocity and the equivalent mobilities of the source and the receiving structure. The input data are determined in third-octave frequency bands. Simplified expressions are used according to the source and receiver equivalent mobility ratio. The installed power value obtained can then be used as input data for a model predicting structure-borne noise levels on site. The reference source is characterized from laboratory measurements. The installed power is predicted for two different receivers: a heavy concrete floor and a lightweight wooden floor; their equivalent mobilities are estimated or measured. The calculated installed power values are presented and compared to experimental results. This provides information about the accuracy of the power expressions used.
机译:这项工作旨在使用基于等效量的近似表达式来预测参考源的已安装结构声功率。根据源等效自由速度以及源与接收结构的等效迁移率计算安装的功率水平。输入数据在三倍频程频段中确定。根据源和接收器的等效迁移率,使用简化的表达式。然后,所获得的安装功率值可以用作模型的输入数据,该模型可以预测现场的结构噪声水平。参考源通过实验室测量来表征。可以预测两种不同接收器的安装功率:重型混凝土地板和轻质木地板;估计或测量它们的等效迁移率。将显示计算出的安装功率值,并将其与实验结果进行比较。这提供了有关所使用的幂表达式的准确性的信息。