The measurement of the transmission loss of building elements is typically performed according to ISO 140, by measuring the sound pressure level in the sending and receiving room, using standardized loudspeaker-microphone instrumentation. Recent proposals for new building acoustic standards taking into account frequencies down to 50 Hz, provoke new questions. At low frequencies (depending on the dimensions of the rooms), the modal density in the rooms is typically too low, impeding reliable measurements following standard techniques. In this paper the vibration level and distribution of the element is determined by means of advanced laser Doppler vibrometer measurements and the radiated sound power of the element is subsequently determined by means of numerical simulations that use the measured velocity distribution as input boundary condition. This approach to deduce the transmission loss is compared with the classical way of measuring the radiated sound.
机译:建筑构件传输损耗的测量通常是根据ISO 140标准,通过使用标准的扬声器-麦克风仪器测量发送和接收室中的声压级来进行的。考虑到低至50 Hz的频率的最新建筑声学标准提案,提出了新的问题。在低频下(取决于房间的尺寸),房间中的模态密度通常太低,妨碍了采用标准技术进行可靠的测量。在本文中,通过先进的激光多普勒振动计测量来确定元件的振动水平和分布,然后通过将测得的速度分布作为输入边界条件的数值模拟来确定元件的辐射声功率。将这种推导传输损耗的方法与经典的辐射声测量方法进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号