首页> 外文会议>Chinese Control and Decision Conference >A time-difference PLS based soft sensor method of underflow concentration for thickener in hydrometallurgy
【24h】

A time-difference PLS based soft sensor method of underflow concentration for thickener in hydrometallurgy

机译:氢灰尘冶金增稠剂下溢浓度的基于时间差的PLS软传感器方法

获取原文

摘要

To address the real-time measurement problem of underflow slurry concentration in hydrometallurgy, a soft sensor method based on time-difference partial least square (TD-PLS) is proposed. The time difference is utilized to overcome the data misalignment problem caused by the slurry crystal on the surface of sensors. The input secondary variables of the method are time difference press value relative to the initial time, and all the press sensors located in different depth, while the output is the corresponding time difference value of underflow slurry concentration relative to the initial concentration. It is essential that the initial slurry concentration should be measured precisely. A large amount of data is used to training the soft sensor model, and the method can estimate the real-time thickener underflow slurry concentration accurately. The method is applied to a thickener in certain refinery, and the measurement error is in the allowable deviation.
机译:为了解决潮湿冶金中下流浆料浓度的实时测量问题,提出了一种基于时差部分最小二乘(TD-PL)的软传感器方法。利用时间差来克服由传感器表面上的浆料晶体引起的数据未对准问题。该方法的输入次级变量是相对于初始时间的时差按值,并且位于不同深度的所有压制传感器,而输出是底流浆料浓度相对于初始浓度的相应时间差值。必须精确测量初始浆料浓度至关重要。大量数据用于训练软传感器模型,并且该方法可以精确估计实时增稠剂下流浆料浓度。该方法应用于某种炼油厂的增稠剂,测量误差处于允许偏差。

著录项