首页> 外文会议>European Conference on Power Electronics and Applications >Individual capacitor voltage balancing in H-bridge cascaded multilevel STATCOM at zero current operating mode
【24h】

Individual capacitor voltage balancing in H-bridge cascaded multilevel STATCOM at zero current operating mode

机译:在零电流运行模式下H-Bridge级联多级别级别的单个电容电压平衡

获取原文

摘要

Individual capacitor voltage balancing is one of the challenges in the field of multilevel converters, especially when the phase legs of the converter are connected in star configuration. This issue can be even more problematic when the converter is operating close to zero average current operating mode. This paper first shows the issue related to the capacitor voltage balancing at zero average-current mode and second proposes a novel algorithm to overcome this problem. The method proposes a modulation technique for individual balancing in H-bridge cascaded multilevel converters operated at zero average-current mode. The proposed algorithm modifies the conventional sorting algorithm based on current ripple. The individual DC-link voltage control method is applied to a 19-level star-connected cascaded converter in PSCAD and simulation results verify the ability of the proposed method in maintaining the balancing of the capacitors voltages at zero current injection mode. Several practical limitation such as forward voltage drop over semiconductor elements, noise in measured data, delay in the digital controller, switching deadtime, and grid voltage harmonics are also considered in the model.
机译:单个电容器电压平衡是多级转换器领域的挑战之一,特别是当转换器的相腿以星形配置连接时。当转换器靠近零平均电流运行模式时,此问题可能更为问题。本文首先显示了与零平均电流模式下电容器电压平衡相关的问题,第二个提出了一种克服这个问题的新算法。该方法提出了一种在零平均电流模式下操作的H桥级联的多电梯转换器中单个平衡的调制技术。所提出的算法根据电流纹波修改传统的分类算法。在PSCAD中将各个DC-Link电压控制方法应用于19级星连接的级联转换器,仿真结果验证了所提出的方法在零电流喷射模式下保持电容器电压的平衡方面的能力。在模型中也考虑在模型中也考虑了诸如半导体元件上的正半导体元件,测量数据噪声,延迟,切换死区和电网电压谐波等几种实际限制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号