As the real sample diagnosis using resonance-based microcantilevers, a simple method is strongly suggested that capture probe immobilized on the cantilever directly hybridize with nanoparticles conjugated detection probe. Two different dimensions of microfabricated piezoelectric cantilevers and two different sizes of nanoparticles were used in this experiment. As a result, the most suitable conditions, the 30 × 90 μm{sup}2 (width × length) of the cantilever and the 140nm of the nanoparticles, were chosen for this method. And quantitative analysis was carried out in different concentrations of nanoparticles conjugated detection probe which are 1 μg/mL, 10 μg/mL and 100 μg/mL. In addition, the sensitivity of this method was demonstrated through the SNP (single nucleotide polymorphism) detection by comparing with quantitative data of hybridization in full matched sequence at same concentration.
机译:作为使用基于共振的微电子的真实样本诊断,强烈建议一种简单的方法,即固定在悬臂上的捕获探针直接与纳米颗粒共轭检测探针杂交。本实验中使用了两种不同尺寸的微制造压电悬臂和两种不同尺寸的纳米颗粒。结果,选择最合适的条件,悬臂的30×90μm{sup} 2(宽度×长度)和纳米颗粒的140nm,用于该方法。并在不同浓度的纳米颗粒共轭检测探针中进行定量分析,其为1μg/ ml,10μg/ ml和100μg/ ml。此外,通过与相同浓度的完全匹配序列中的杂交的定量数据相比,通过SNP(单核苷酸多态性)检测来证明该方法的敏感性。