Code validation on qualified experimental data is a fundamental issue in the design and safety analyses of nuclear power plants.The SPES3 facility is being built at the SIET laboratories for an integral type SMR simulation, in the frame of an R&D program on nuclear fission, funded by the Italian Ministry of Economic Development and led by ENEA.The facility, based on the IRIS reactor design, reproduces the primary, secondary and containment systems with 1:100 volume scale, full elevation and prototypical fluid and thermal-hydraulic conditions. It is suitable to test the plant response to design and beyond design accidents in order to verify the effectiveness of the primary and containment system dynamic coupling to cope with loss of coolant accidents. Full and complete nodalizations of SPES3 were developed for TRACE and RELAP5 codes in order to investigate the code response to the simulation of the same accidental transient. The DVI line DEG break was simulated in beyond design conditions, assuming the failure of all emergency heat removal systems and relying on PCC intervention for containment depressurization and decay heat removal. The comparison of the code simulation results, other than providing information on the system behavior, allowed to investigate specific phenomena evidenced by the codes, according to the related modeling approach of components with one and three-dimensional volumes.The TRACE and RELAP5 codes will be applied for further transient analyses and will be validated on SPES3 experimental-data, once the facility will be available.
机译:在核电厂的设计和安全分析中,对合格实验数据进行代码验证是一个基本问题。在核裂变研究与开发计划的框架内,SIET实验室正在为SIET实验室建造SPES3装置,以进行整体式SMR模拟。该设施由意大利经济发展部和ENEA领导。该设施基于IRIS反应堆设计,以1:100的体积比例,全高程和原型流体及热工水力条件复制了一次,二次和安全壳系统。它适合于测试工厂对设计事故和超出设计事故的响应,以验证主系统和安全壳系统动态耦合器的有效性,以应对冷却剂事故的损失。为研究TRACE和RELAP5代码开发了SPES3的完整和完全节点化,以便研究代码对相同意外瞬态仿真的响应。假设所有应急排热系统均出现故障,并依靠PCC干预进行安全壳减压和衰减排热,则在超出设计条件的情况下模拟了DVI线DEG中断。代码仿真结果的比较除了提供系统行为的信息外,还可以根据具有一维和三维体积的组件的相关建模方法来研究由代码证明的特定现象.TRACE和RELAP5代码将是可以用于进一步的瞬态分析,一旦设施可用,将在SPES3实验数据上进行验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号