首页> 外文会议>International conference on environmental odour monitoring and control >Online or Delayed Olfactometry - a Comparison Based on Results from Four Different Types of Pig Housing or Mitigation Systems
【24h】

Online or Delayed Olfactometry - a Comparison Based on Results from Four Different Types of Pig Housing or Mitigation Systems

机译:在线或延迟的嗅觉测量 - 基于来自四种不同类型的猪外壳或缓解系统的结果进行比较

获取原文

摘要

The performance of on-site measurements by dynamic olfactometry using a mobile laboratory with online measurements was compared with delayed olfactometric analysis carried out by two external laboratories using the same kind of olfactometer as the mobile laboratory. All sampling and analyses were performed according to CEN 13725:2003, and analyses at the external laboratories were carried out within 24 hours of sampling. Sampling was not performed at the mobile laboratory, since the olfactometer was connected directly to the source with a heated sampling tube. In total, results for 120 odour measurements, representing four different types of pig housing or mitigation systems, were compared. Due to the direct connection between the olfactometer and the source in the mobile laboratory, there was no time delay or other effects (e.g. sampling bags, temperature or condensation) that could affect the results. The number of panellists used in the mobile laboratory was lower than that used in one of the two external laboratories. The results for each sample were compared in order to evaluate the overall performance of the three laboratories with regard to concentration levels and variance. The study shows a statistically significant difference between the results from the three laboratories. The variance in the mobile laboratory with online measurements was lower than that in the two laboratories using delayed olfactometry, and most of the difference was due to day-to-day variance.
机译:将使用与在线测量的动态嗅觉测量进行动态嗅觉测量的现场测量的性能与两个外部实验室使用相同类型的嗅觉计作为移动实验室进行的延迟嗅觉分析。所有取样和分析均按CEN 13725:2003进行,并在外部实验室的分析在抽样的24小​​时内进行。在移动实验室没有进行采样,因为嗅觉表直接连接到带加热的采样管的源极。相比,总共有120种异味测量的结果,而是比较了四种不同类型的猪壳或缓解系统。由于嗅觉计和移动实验室的源之间的直接连接,没有时间延迟或其他影响(例如,采样袋,温度或缩合)可能影响结果。移动实验室中使用的小组成员数量低于两个外部实验室中的一个。比较每个样品的结果,以评估三个实验室的整体性能,方面的浓度水平和方差。该研究表明,三个实验室的结果之间存在统计学上的差异。在线测量的移动实验室的差异低于使用延迟嗅觉测量的两个实验室中的差异,并且大多数差异是由于日常方差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号