Application of AC low-voltage technology is introduced in this paper, and the essentiality of AC low voltage''s verification is indicated. Respective discussed some methods applied in AC low voltage meter verification, include method of resistance divider, method of inductive divider, method of AC-DC transfer and method of standard source. Principle and actuality development of those four methods be expatiated. At the last the characteristic and specification of an AC low voltage standard source is introduced, this instrument manufactured by our Institute, which consist of 10V voltage reference, 7-bit programmable decimal divider, sine wave generator and low noise programmable divider, voltage reference be used to change amplitude of standard output, sine wave generator be used to output AC voltage signal, low noise divider be used to generate AC low voltage, uncertainty is 120×10−6 mV at 10 mV 1 kHz.
机译:介绍了交流低压技术的应用,指出了交流低压验证的必要性。分别讨论了应用于交流低压仪表校验的一些方法,包括电阻分压器方法,电感分压器方法,交直流转换方法和标准电源方法。阐述了这四种方法的原理和现实发展。最后介绍了由我所制造的交流低压标准电源的特性和规格,该仪器由10V电压基准,7位可编程十进制分频器,正弦波发生器和低噪声可编程分压器组成,电压基准为用于改变标准输出的幅度,使用正弦波发生器输出交流电压信号,使用低噪声分压器产生交流低压,在10 mV 1 kHz时不确定度为120×10 −6 mV 。