In order to solve problems in conventional hepatic functional reserve analysis, such as multiple blood sampling, long time consuming and needing for concentration of hemoglobin, current study presents a new method to analysis hepatic function reserves based on pulse dye density. Indocycanine green was injected to patients' veins. Then, dual-wavelength pulse wave data were collected from patients' finger with photoplethysmography sensor which contained 940nm and 805nm light-emitting diodes. The rate of concentration changes of indocycanine in blood could be calculated by analyzing pulse wave data. By comparing experimental findings, the relative error of the method is less than 5%. Under the premise of simplified procedure, the method meet the purpose of non-invasive liver function reserve detection, provides reference materials fro preoperative preparation.
机译:为了解决常规肝功能储备分析中的问题,例如多次采血,耗时长,需要血红蛋白浓缩等,目前的研究提出了一种基于脉冲染料密度分析肝功能储备的新方法。吲哚青绿被注入患者的静脉。然后,用装有940nm和805nm发光二极管的光电体积描记器从患者的手指采集双波长脉搏波数据。通过分析脉搏波数据可以计算出血液中吲哚卡因的浓度变化率。通过比较实验结果,该方法的相对误差小于5%。在简化程序的前提下,该方法符合无创肝功能储备检测的目的,为术前准备提供参考资料。