PROSPECT ON THE LOCA ANALYSIS METHOD ON THE ADVANCED PRESSURIZED WATER REACTOR IN CHINA

机译:中国先进加压水反应器LOCA分析方法的展望

获取原文

摘要

The LOCA analysis for the advanced pressurized water reactor (PWR) is very important and the methods on it are developing. There are two basic approaches for LOCA (loss of coolant accident) licensing at current. One is based on the conservative requirement of Appendix K of 10CFR50.46 of USNRC, and another is the best estimate (BE) analysis methodology which needs strict sensitivity and uncertainty analysis. The results achieved by the best estimate analysis are closer to the reality than those achieved by the conservative methodology, and the realistic BELOCA analysis in nuclear realm becomes an international trend currently although its development still meet lots of challenges.The research and design on AP1000 to be built in China and larger advanced pressurized water reactor (CAP 1400 or CAP 1700) as one of Chinese national science & technology major project is in progress. The reliable licensing LOCA analysis as one of the most important accident safety analysis is absolutely necessary. There are three ways to get the code applied in licensing accident analysis: the first way is developing code based on the best estimated methodology with strict uncertainty analysis, the second way is to develop new analysis code based on the conservative Appendix K, and the third way is improving the current system analysis code, which had been verified and validated by many cases, to satisfy the requirements of Appendix K. The last one may be the most feasible way for the AP1000 design with high efficiency and economic competition. Some code like RELAP5 has been used for LOCA analysis, and its results showed good agreement with the test data. RELAP is the transient thermal-hydraulic system analysis code developed by Idaho National Laboratory, in which some model and correlations are not consistent with the conservative requirements of Appendix K, so it can not be applied for licensing LOCA analysis and evaluation directly. In this paper the way to develop analysis code for LOCA license is discussed, and some areas in RELAP code needed to be modified for according with Appendix K are also described,which will be helpful for the advanced PWR design and development in China.
机译:先进压水堆(PWR)的LOCA分析非常重要,并且正在开发有关方法。当前,有两种基本方法可用于LOCA(冷却液损失事故)许可。一种是基于USNRC 10CFR50.46附录K的保守要求,另一种是最佳估计(BE)分析方法,需要严格的敏感性和不确定性分析。最佳估计分析所获得的结果比保守方法所获得的结果更接近于现实,尽管在核领域进行现实的BELOCA分析仍面临许多挑战,但目前已成为国际趋势。 作为中国国家科技重大专案之一,拟在中国建造的AP1000和大型先进压水堆(CAP 1400或CAP 1700)的研究和设计正在进行中。作为最重要的事故安全分析之一,可靠的许可LOCA分析是绝对必要的。有三种方法可以将代码应用到许可事故分析中:第一种方法是基于具有严格不确定性分析的最佳估计方法开发代码,第二种方法是基于保守的附录K开发新的分析代码,第三种方法是一种方法是改进目前经过许多案例验证和验证的系统分析代码,以满足附录K的要求。最后一种可能是AP1000设计的最可行方法,具有较高的效率和经济竞争性。诸如RELAP5之类的代码已用于LOCA分析,其结果与测试数据显示出良好的一致性。 RELAP是爱达荷州国家实验室开发的瞬态热工液压系统分析代码,其中的某些模型和相关性与附录K的保守要求不一致,因此不能直接用于许可LOCA分析和评估。本文讨论了LOCA许可证分析代码的开发方法,并介绍了需要根据附录K进行修改的RELAP代码中的某些方面,这将有助于中国先进的PWR设计和开发。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号