This paper describes a study into the possibility of using Japanese cedar as fire-protection for steel framed apartment building. Loaded fire resistance tests on three full-scale steel tube columns protected by cedar were carried out. The width of cross section of square steel tube is 400mm and the thickness is 16mm. The height of steel tube is 3500mm. The thickness of cedar plates is 60mm. The specimens were heated by the ISO 834 standard fire tempera ture curve. The heating time for specimens A and B was 60 minutes during the loaded fire resistance test The re sults of specimens A and B verified that steel tubes protected by cedar plates of 60mm thick satisfied the required 60-minute fire resistance rating according to the current Japanese regulations. The reasons for the collapse of speci men C were discussed and the thermal expansion of specimen C was simulated by calculation.
机译:本文描述了对使用日本柳杉作为钢框架公寓楼防火的可能性的研究。在三根由雪松保护的全尺寸钢管柱上进行了耐火测试。方钢管的横截面宽度为400mm,厚度为16mm。钢管的高度为3500mm。雪松板的厚度为60mm。通过ISO 834标准着火温度曲线加热样品。在负荷耐火试验中,样品A和B的加热时间为60分钟。样品A和B的结果证实,根据当前的日本标准,用60mm厚的雪松板保护的钢管满足要求的60分钟耐火等级规定。讨论了试样C坍塌的原因,并通过计算模拟了试样C的热膨胀。