摘要

Electrostatic accidents happened at many filling stations have been analyzed, and the static electrification mechanisms and several conventional static forms have been analyzed according to the double electric layer theory. The conditions of generating and releasing of the static electricity have been introduced. Electrostatic accumulation, combustible gas with a certain concentration and spark discharge of static electricity are the conditions for engendering static hazard at filling station. The basic way for eliminating the static disaster has been summarized according to the mechanism of static electrification, the conditions of electrification and release of static electricity. Finally, the safety management and control measures of static accident at filling station have been proposed.
机译:分析了许多加油站发生的静电事故,并根据双电层理论分析了静电起电机理和几种常规的静电形式。已经介绍了产生和释放静电的条件。静电积累,一定浓度的可燃气体和静电火花放电是在加油站产生静电危害的条件。根据静电的产生机理,静电的产生和释放的条件,总结了消除静电灾害的基本方法。最后,提出了加油站静态事故的安全管理和控制措施。