This paper presents a study aiming the project of efficient monophase distribution transformers to be used in regions of low energy demand. In these regions, due to the clients profile, no load losses are more expressive than losses in copper. The study necessary for the realization of this work was based on a survey accomplished by AES Sul — Distribuidora Gaúcha de Energia in partnership with the High Voltage Laboratory of Federal University of Itajubá — LAT-EFEI. Through this study, it was found that most of the transformers in rural area operate with low demand, not exceeding, in some cases, the limit of 0, 3 p.u. In these conditions, it is necessary to prioritize the reduction of no load losses so that the transformer can operate efficiently. This work introduces an analysis based on optimization of the percent impedance of the monophase distribution transformer aiming the reduction of losses in the core, indicating that on contrary to common sense, the increase of the percent impedance can result in a transformer with low costs and low no load losses, presenting reduced total losses if used under indicated loading conditions.
机译:本文提出了一项针对低能耗地区高效单相配电变压器项目的研究。在这些地区,由于客户的不同,没有负载损失比铜的损失更具表现力。实现这项工作所必需的研究是基于AES Sul(DistribuidoraGaúchade Energia)与Itajubá联邦大学高压实验室(LAT-EFEI)合作完成的一项调查。通过这项研究发现,农村地区的大多数变压器的需求量很低,在某些情况下不超过0、3 p.u的极限。在这些条件下,有必要优先降低空载损耗,以使变压器能够高效运行。这项工作介绍了一种基于优化单相配电变压器阻抗百分比的分析,旨在减少铁芯中的损耗,这表明,与常识相反,阻抗百分比的增加可能会导致变压器的成本降低,成本降低。无负载损失,如果在指定的负载条件下使用,则总损失减少。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号