Estimation of ICRU operational quantity Hp(0.07) has been carried out usingthermoluminescence dosemeter (TLD) system based on CaSO_4:Dy phosphor embedded disc for threedifferent beta sources. The dose evaluation algorithm developed previously was first used for itssuitability in terms of accuracy. Subsequently the old algorithm was modified to meet the accuracy limitas per IEC standard. The modified algorithm was tested for mixed fields of beta and gamma radiation.Angular response of the TLD badge system in terms of Hp(0.07) was also evaluated using the modifiedalgorithm It was found that using the modified algorithm it is possible to estimate Hp(0.07) within theaccuracy limit laid down by IEC for ~(90)Sr-~(90)Y and ~(85)Kr beta sources. However for 147Pm unless the designof the TLD badge is changed it is difficult to meet the accuracy limit of IEC.
机译:使用以下方法估算了ICRU的运行量Hp(0.07) CaSO_4:Dy荧光粉嵌入式光盘的热发光剂量计(TLD)系统用于三个 不同的Beta来源。先前开发的剂量评估算法首次用于 在准确性方面的适用性。随后,对旧算法进行了修改以满足精度限制 按照IEC标准。测试了修改后的算法中β和γ辐射的混合场。 还使用改进版评估了TLD徽章系统在Hp(0.07)方面的角响应 算法发现使用改进的算法可以估计Hp(0.07) IEC对〜(90)Sr-〜(90)Y和〜(85)Kr beta源确定的精度极限。但是对于147Pm,除非设计 TLD徽章的标志已更改,很难满足IEC的精度限制。