Experience Of Screen Tube Damage Caused By Falling Deposits In Kraft Recovery Boilers

机译:牛皮纸回收锅炉沉积沉积物造成的屏幕损伤体验

获取原文

摘要

An investigation was conducted to examine the cause of severe screen tube damage in the recovery boiler at VCP Luis Antonio mill. The results suggest that the problem was likely caused by impact of large pieces of deposits falling from the furnace roof and from the leading edge of superheater platens in the upper furnace. The problem has been reduced significantly by periodically monitoring the amount of deposit buildup on the furnace roof using a special camera; by installing an additional sootblower to minimize the deposit accumulation; by increasing the pressure and blowing frequency of sootblowers to minimize deposit build up in the problem-prone areas and by induced thermal shedding to control deposit size.
机译:进行了调查,以研究VCP Luis Antonio Mill在VCP Luis Antonio Mill中复制锅炉严重筛管损伤的原因。结果表明,大量沉积物从炉屋顶和上炉中的超健器压板的前缘的影响可能会引起问题。通过使用特殊相机定期监测炉屋顶上的沉积物堆积量的情况显着减少了问题;通过安装额外的临时通可者以最小化沉积物积累;通过提高烟道钳的压力和发泡频率,以最小化问题易于沉积物的沉积物,并通过诱导热脱落来控制沉积物尺寸。