PG-7 antitank rocket grenades are widely used in contemporary asymmetrical conflicts. Designing countermeasures against them needs some data characterizing the action of the grenades. One of the most important factor is the initiation time, defined by the authors as a time span between the moment of impact of the grenade at a target to the moment when shaped charge jet reaches the target. Results of measurements of the initiation time are presented in the paper. The mean value of the initiation time and the confidence range of its values are determined. Possible sources of observed scatter of the initiation time values are discussed on the basis of measured values of the reaction time of primer IED used in PG-7 grenades, as well as results of measuring voltage pulses produced by the grenade cap in a drop test.
机译:PG-7 Antitrank火箭手榴弹广泛用于当代不对称冲突。针对它们的设计对策需要一些数据表征手榴弹的动作。最重要的因素之一是启动时间,由作者定义为时跨在朝向目标电荷射流到达目标时的瞄准的时刻之间的时间跨度。纸张中提出了启动时间的测量结果。确定起始时间的平均值和其值的置信范围。基于PG-7手榴弹中使用的引物的反应时间的测量值讨论了所观察到的发起时间值的可能源,以及测量通过榴弹帽在滴测试中产生的电压脉冲的结果。