首页> 外文会议>2nd IEEE Energy Conversion Congress and Exposition >Overvoltage mitigation of inverter-driven motors with long cables of different lengths
【24h】

Overvoltage mitigation of inverter-driven motors with long cables of different lengths

机译:各种长度的长电缆的变频器驱动电机的过电压缓解

获取原文

摘要

This paper presents an intensive discussion on an overvoltage appearing at the motor terminals of an adjustable-speed drive that consists of a voltage-source PWM inverter, an induction motor, and a three-phase symmetric long cable. It describes a design procedure for a simple passive EMI filter based on parallel connection of an inductor and a resistor, which is intended for mitigating the overvoltage at the motor terminals. The modeling of the cable and the motor are prominent in focusing on the natural frequency or ringing frequency inherent in the cable used, which is inversely proportional to cable length. Impedance mismatch at the inverter and motor terminals causes the overvoltage that may reach double the inverter dc-link voltage. The effectiveness and validity of the simple design procedure of the filter are confirmed on the 400-V, 15-kW experimental system with either a 100-m or 200-m-long cable, as well as on computer simulation based on the modeling of the cable and the motor.
机译:本文对由电压源PWM逆变器,感应电动机和三相对称长电缆组成的变速驱动器的电动机端子上出现的过电压进行了深入的讨论。它描述了基于电感器和电阻器并联的简单无源EMI滤波器的设计程序,该程序旨在减轻电动机端子上的过电压。电缆和电动机的建模在着重于所用电缆固有的固有频率或振铃频率方面尤为突出,该固有频率或振铃频率与电缆长度成反比。逆变器和电动机端子处的阻抗不匹配会导致过电压,该过电压可能达到逆变器直流母线电压的两倍。滤波器简单设计程序的有效性和有效性在使用100 m或200 m长电缆的400 V,15 kW实验系统上以及基于以下模型的计算机仿真中得到了证实电缆和电动机。