The U.S. Navy has now developed an N-Class division system to classify fire resistantboundaries in accordance with MIL-STD-3020, Fire Resistance on U.S. Naval Surface Ships [1].The N-Class division is analogous to the commercial International Maritime Organization (IMO)system (e.g. A-Class) division. The key difference is that N-Class divisions are designed to havesatisfactory fire resistance when exposed to hydrocarbon pool fire (UL 1709 fire exposure)following a shock event. In addition, N-Class is applicable to fire resistant divisions constructedfrom polymer composites structures when they meet the requirements of DDS-078-1 [2].MIL-STD-3020 [1] requires a hydrocarbon pool fire exposure (UL-1709 fire exposure) whichprovides a minimum average total heat flux of 188 kilowatts per square meter (kW/m2) (60,000Btu per square foot/hour (Btu/ft2-h)) within the first 5 minutes of the test exposure. At all timesafter 5 min, the average temperature within the furnace shall be maintained at a minimum of1038 °C (1900 °F) and a maximum of 1149 °C (2100 °F) for the duration of the test. These fireconditions simulate a post-flashover fire scenario for shipboard applications. Performance isdefined as the time period during which assemblies will continue to perform their intendedfunction when subjected to fire exposure. The minimum duration of fire exposure is 30 minutes.Shock testing prior to fire resistance test is performed to ensure that fire resistance of divisions,with fire insulation, penetrations, and associated attachment methods, is not degraded in acombat environment. Shock test specimen size of 1219 by 3048 mm (4 by 10 feet) was selectedto reduce the cost of shipping a full size fire test specimen of 3048 by 3048 mm (10 by 10 feet)or greater to the fire test laboratory. A full scale fire resistance test is still required forqualification purposes after successful completion of the shock test prior to fire resistance test.MIL-STD-3020 [1] also permits AN-Class fire resistant divisions when fire threat is fromcommon combustibles (Class A) and where liquid flammable (Class B) fire threat is nonexistent.AN-Class divisions are those divisions formed by bulkheads and decks that are designed toprotect against structural failure and prevent the passage of flame or hot gases when exposed toIMO Resolution A.754(18) fire exposure [3] after shock testing. For all AN-Class divisions,including those with penetrations, the fire test duration is a minimum of 60 minutes.This paper will discuss fire resistance test results conducted using steel, aluminum, andcomposite substrates.
机译:美国海军现在已经开发了N级划分系统来对耐火性进行分类 边界符合MIL-STD-3020,美国海军水面舰艇的耐火性[1]。 N级部门类似于商业国际海事组织(IMO) 系统(例如A级)部门。关键区别在于N级师级的设计旨在 暴露在碳氢化合物池火灾中时具有令人满意的耐火性(UL 1709火灾暴露) 发生电击事件后此外,N级适用于建造的耐火分区 当它们满足DDS-078-1 [2]的要求时,就可以从聚合物复合材料结构中分离出来。 MIL-STD-3020 [1]需要碳氢化合物池着火(UL-1709着火), 提供的最小平均总热通量为188千瓦/平方米(kW / m2)(60,000 在测试暴露的前5分钟内,每平方英尺/小时的Btu(Btu / ft2-h)。每时每刻 5分钟后,炉内的平均温度应至少保持在 测试期间,最高温度为1038°C(1900°F),最高为1149°C(2100°F)。这些火 条件模拟了舰载应用的闪络后火灾场景。表现是 定义为程序集将继续执行其预期的时间段 暴露于火中时起作用。火灾的最短持续时间为30分钟。 在进行耐火性测试之前先进行冲击测试,以确保分区的耐火性, 具有防火隔热,穿透力和相关联结方法的材料,在使用过程中不会降低 战斗环境。选择的冲击试验样本尺寸为1219 x 3048毫米(4 x 10英尺) 减少3048毫米的全尺寸防火测试样品的运输成本3048毫米(10乘10英尺) 或更高的耐火测试实验室。仍然需要全面的耐火测试 合格目的是在成功完成冲击试验后才能进行耐火试验。 当发生火灾威胁时,MIL-STD-3020 [1]还允许进行AN级耐火师 常见的可燃物(A类)和不存在液体可燃物(B类)的火灾隐患。 AN级分隔是指由舱壁和甲板构成的分隔, 防止结构故障,并防止火焰或热气在暴露于空气中时通过 冲击测试后,IMO决议A.754(18)着火[3]。对于所有AN级部门, 包括穿透的那些,耐火测试持续时间至少为60分钟。 本文将讨论使用钢,铝和铝进行的耐火测试结果 复合基材。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号