首页> 外文会议>8th International Conference on Advances in Power System Control, Operation and Management >The current transformer model with ATP-EMTP for transient response characteristic and its effect on differential relays performnce
【24h】

The current transformer model with ATP-EMTP for transient response characteristic and its effect on differential relays performnce

机译:具有ATP-EMTP的电流互感器模型的瞬态响应特性及其对差分继电器性能的影响

获取原文

摘要

This paper presents the analysis of current transformer transients. The model is constructed on EMTP (Electromagnetic Transients Program). In the current transformer model, the secondary winding is connected in parallel with a magnetizing branch with non-linear characterestics of the inductor. Type-96 pseudo non-linear hysteristic inductor with saturation and hysteresis charecteristics is used incorporated with the sub-programs “SATURA” and “HYSDAT”. These programs are employed in data of saturation and for input data of the inductor. The analysis is taken into account effect of, burdens, accuracy classes on current transformer performances. Data protection system of 20 MVA and 75 MVA power transformers are used in the study. The results can be used for the programma model Freja 300 relay testing machine system for operating performances of the relay. In addition, appropriate current transformer and protection relays can be selected based on the results.
机译:本文介绍了电流互感器瞬态的分析。该模型基于EMTP(电磁瞬态程序)构建。在电流互感器模型中,次级绕组与具有电感器非线性特性的励磁支路并联连接。具有饱和和磁滞特性的96型伪非线性磁滞电感器与子程序“ SATURA”和“ HYSDAT”结合使用。这些程序用于饱和数据和电感器的输入数据。该分析考虑了负担,精度等级对电流互感器性能的影响。研究中使用了20 MVA和75 MVA电力变压器的数据保护系统。该结果可用于程序模型Freja 300继电器测试机系统,以了解继电器的工作性能。此外,可以根据结果选择合适的电流互感器和保护继电器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号