During an annual inventory of nuclear material, a plated steel container which contained plutonium oxide failed. The container had been packaged for temporary storage but had been overlooked and remained in storage for more than 23 years. Although it was determined that the failure occurred through the slip-top rim, a metallurgical evaluation was requested to help to determine the integrity of the container.Optical metallography and scanning electron microscopy were used to analyze the character and degree of corrosion in the container. The depth of corrosion, measured at approximately 10 jam, did not pose a threat to the integrity of the container. However, the corrosion morphology and chemistry did suggest that a galvanic cell had developed between the tin and steel from the condensation of water. The morphology also suggests that the attack of the steel took place over a series of cycles due to changes of the environment.
机译:在核材料的年度库存期间,装有氧化oxide的电镀钢容器发生了故障。该容器已经包装好以用于临时存储,但是却被忽略了,并且在存储中已经保存了23年以上。尽管确定故障是通过滑顶边缘发生的,但仍要求进行冶金评估以帮助确定容器的完整性。 使用光学金相学和扫描电子显微镜分析了容器中腐蚀的特征和程度。腐蚀深度约为10卡纸,对容器的完整性没有构成威胁。但是,腐蚀的形态和化学成分确实表明,由于水的冷凝,在锡和钢之间形成了原电池。形态还表明,由于环境的变化,钢的腐蚀发生了一系列循环。