Auto-refrigeration of carbon-steel equipment during abnormal events is an ongoing concern inethylene units. In late 2002, while changing out a power supply on the electronic governor forthe propylene refrigeration compressor turbine drive at Chevron Phillips Chemical’s Port ArthurEthylene Unit, the turbine tripped resulting in loss of refrigeration to the ethylene fractionatoroverhead condensers. As the tower warmed up and the pressure increased, the pressurecontrolled flare dump valves and the pressure relief valves opened to the flare system. One ofthe pressure relief valves failed to close causing the tower to depressure down to 12 psig.This presented a potential brittle fracture hazard for an impact tested carbon steel tower.The paper will review the incident, the response that brought the tower to a safe state, andthe mechanical reliability evaluation performed to ensure the tower was safe to re-pressurizeand start up.
机译:碳钢设备在异常情况下的自动制冷一直是人们关注的焦点。 乙烯单元。在2002年下半年,在更换电子调速器上的电源时, 雪佛龙菲利普斯化工公司亚瑟港的丙烯制冷压缩机涡轮驱动器 乙烯装置,涡轮机跳闸,导致乙烯分馏器的制冷损失 高架冷凝器。随着塔的升温和压力的增加,压力 控制的火炬排放阀和向火炬系统打开的泄压阀。之一 泄压阀无法关闭,导致塔筒减压至12 psig。 这对经过冲击测试的碳钢塔架提出了潜在的脆性断裂危险。 本文将回顾事件,使塔楼进入安全状态的响应,以及 进行机械可靠性评估,以确保塔筒可以安全地重新加压 然后开始