Elasto-plastic behavior of high-strength bolted friction joints for steel beam-to-diaphragm connections

机译:用于钢梁到隔膜连接的高强度螺栓摩擦接头的弹塑性行为

获取原文

摘要

Bolted bea beam-to-diaphragm connections are often critical sections to under earthquake stresses. The Architectural Institute of Japan (AIJ) has recommended a coefficient for joints as a safety factor:α(y)=1.0 to allow beam yield and α(u) = 1.10 1.25 to prevent rupture. However, the target for these coefficients is beam-to-beam joints subject to comparatively small stresses in welded diaphragm connections. In this study, eight cantilever-beam-type specimens incorporating bolted friction joints were cyclically loaded to determine a suitable joint coefficient to meet the AIJ recommendation. Test results and calculations led to conclusion that for grade of SS400 (mild steel), α(y) needs to be greater than ζ (bending moment gradient), and α(u) needs to be over 1.35.
机译:螺栓的BEA波束 - 光圈连接通常是在地震应力下的关键部分。日本建筑研究所(AIJ)已经推荐了关节作为安全因子的系数:α(y)= 1.0允许光束产量和α(u)= 1.10 1.25以防止破裂。然而,这些系数的目标是受焊接隔膜连接中的相对小的应力的光束接头。在这项研究中,循环加载八个包含螺栓摩擦接头的悬臂式型样品以确定合适的关节系数,以满足AIJ推荐。测试结果和计算导致得出结论,对于SS400等级(低碳钢),α(Y)需要大于△(弯矩梯度),并且α(u)需要超过1.35。