首页> 外文会议>International Symposium on Tubular Structures >Elasto-plastic behavior of high-strength bolted friction joints for steel beam-to-diaphragm connections
【24h】

Elasto-plastic behavior of high-strength bolted friction joints for steel beam-to-diaphragm connections

机译:钢梁到膜片连接的高强度螺栓摩擦接头的弹塑性行为

获取原文

摘要

Bolted bea beam-to-diaphragm connections are often critical sections to under earthquake stresses. The Architectural Institute of Japan (AIJ) has recommended a coefficient for joints as a safety factor:α(y)=1.0 to allow beam yield and α(u) = 1.101.25 to prevent rupture. However, the target for these coefficients is beam-to-beam joints subject to comparatively small stresses in welded diaphragm connections. In this study, eight cantilever-beam-type specimens incorporating bolted friction joints were cyclically loaded to determine a suitable joint coefficient to meet the AIJ recommendation. Test results and calculations led to conclusion that for grade of SS400 (mild steel), α(y) needs to be greater than ζ (bending moment gradient), and α(u) needs to be over 1.35.
机译:螺栓Bea梁到膜片的连接通常是承受地震应力的关键部分。日本建筑学会(AIJ)已建议将连接处的系数作为安全系数:α(y)= 1.0以允许梁屈服,α(u)= 1.101.25以防止破裂。但是,这些系数的目标是在焊接的膜片连接中承受较小应力的梁对梁节点。在这项研究中,八个螺栓连接的悬臂梁型试样被周期性加载,以确定合适的接头系数以满足AIJ的建议。测试结果和计算得出的结论是,对于SS400(低碳钢)等级,α(y)必须大于ζ(弯曲力矩梯度),并且α(u)必须大于1.35。