首页> 外文会议>Image Perception, Observer Performance, and Technology Assessment >Is there a safety-net effect with computer-aided detection (CAD)
【24h】

Is there a safety-net effect with computer-aided detection (CAD)

机译:是否有安全净效果,具有计算机辅助检测(CAD)

获取原文
获取外文期刊封面目录资料

摘要

Computer-Aided Detection (CAD) systems are used to aid readers interpreting screening mammograms. An expert reader searches the image initially unaided, and then once again with the aid of CAD which prompts automatically detected suspicious regions. This could lead to a 'safety-net' effect, where the initial unaided search of the image is adversely affected by the fact that it is preliminary to an additional search with CAD, and may, therefore, be less thorough. To investigate the existence of such an effect, we created a visual search experiment for non-expert observers mirroring breast screening with CAD. Each observer searched 100 images for microcalcification clusters within synthetic images in both prompted and unprompted (no-CAD) conditions. Fifty-two participants were recruited for the study, 48 of whom had their eye movements tracked in real-time; four participants could not be accurately calibrated so only behavioural data was collected. In the CAD condition, before prompts were displayed, image coverage was significantly lower than coverage in the no-CAD condition (t(47)=5.48, p<0.001). Observer sensitivity was significantly greater for targets marked by CAD than the same targets in the no-CAD condition (t(51)=11.67, p<0.001). For targets not marked by CAD, there was no significant difference in observer sensitivity in the CAD condition compared to the same targets in the no-CAD condition (t(51)=0.88, p=0.382). These results suggest that the initial search may be influenced by the subsequent availability of CAD; if so, CAD efficacy studies should account for the effect when estimating benefit.
机译:计算机辅助检测(CAD)系统用于帮助读者解释筛选乳房X光图。专家读者在最初没有内容中搜索图像,然后再次借助CAD再次,提示自动检测到可疑区域。这可能导致“安全净”效果,其中初始唯一的图像搜索受到与CAD的额外搜索初步搜索的事实产生不利影响,因此可能不太彻底。为了调查这种效果的存在,我们为非专家观察者创建了一种视觉搜索试验,镜像乳房筛选用CAD。每个观察者在提示和未突破(No-CAD)条件下,每个观察者都在合成图像中搜索了100个微透析簇。招募了五十二名参与者,为学习,其中48人实时跟踪他们的眼睛运动;无法准确校准四个参与者,因此只收集行为数据。在CAD条件下,在显示提示之前,图像覆盖率明显低于NO-CAD条件下的覆盖率(T(47)= 5.48,P <0.001)。对于由CAD标记的目标比NO-CAD病症中的靶标显着更大(T(51)= 11.67,p <0.001),观察者敏感性明显更大。对于由CAD标记的目标,与NO-CAD条件下的相同目标相比,CAD病症中的观察者灵敏度没有显着差异(T(51)= 0.88,p = 0.382)。这些结果表明,初始搜索可能受到CAD的随后可用性的影响;如果是这样,CAD疗效研究应该在估算效益时算作效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号