Thermal Contraction and Heat Load Characteristicsof the SC Current-Feeder System for LHD

机译:LHD SC电流馈电系统的热收缩和热负荷特性

获取原文

摘要

The superconducting (SC) bus-lines with total length of 497 mare used as the current transmission lines for the experimental fusion device,LHD. Cryostable condition of the SC coils has been kept for more than fivemonths in every experimental campaign. The internal structure of the SCbus line at the bending portions was observed by taking X-ray photographsbefore and after cooling down in 2002. The positions of the SC cable andinner corrugated tubes show good agreement with those of the first coolingdown in 1998. The average heat input into three current-lead cryostats was1.98 - 2.13 W/m2. The average heat load into the thermal shieldingchannels of the SC bus lines was 2.84 - 2.92 W/m. These measured valuesof the heat inputs and heat loads show good agreement with those of thedesigned values.
机译:总长497 m的超导(SC)公交线路 被用作实验融合装置的电流传输线, LHD。 SC线圈的低温状态已保持超过5个 每个实验性活动需要几个月的时间。 SC的内部结构 通过拍摄X射线照片观察弯曲部位的总线 在2002年冷却之前和之后。SC电缆和 内波纹管与第一次冷却的波纹管显示出良好的一致性 在1998年下降。平均输入到三个电流引线式低温恒温器中的热量为 1.98-2.13 W / m2。进入热屏蔽的平均热负荷 SC总线的通道为2.84-2.92 W / m。这些测量值 的热输入和热负荷与 设计值。