摘要

We describe recent tests aimed at eventually realizing a metrological qualityfluorescence-based temperature measurement system. The main advance here is thesubstitution of a deep-blue light emitting diode for a laser source. In this instance, thefluorescing material is crystalline Y2O3:Eu. The measurements range from ambient to800 C. The signal to noise demonstrated is adequate for precise temperaturemeasurement and the expected sensitivity from 600 to 800 C is observed. In addition,some temperature dependence of emission amplitude between ambient and 600 C wasmeasured. Overall, the results are a significant step toward accomplishing viable,inexpensive precision thermometry.
机译:我们描述了旨在最终实现计量质量的最新测试 基于荧光的温度测量系统。这里的主要进步是 用深蓝色发光二极管代替激光源。在这种情况下, 荧光材料是晶体Y2O3:Eu。测量范围从环境温度到 800C。显示的信噪比足以满足精确的温度要求 测量并在600至800 C范围内观察到了预期的灵敏度。此外, 环境温度和600 C之间的发射幅度在一定程度上与温度有关 测量。总体而言,结果是朝着实现可行目标迈出的重要一步, 价格低廉的精密测温仪。