首页> 外文会议>European conference on industrial furnaces and boilers >Scaling-method for the dimensioning of LowNOx-Burners in the capacity range of 15 kW to 350 kW and 2 MW to 10 MW
【24h】

Scaling-method for the dimensioning of LowNOx-Burners in the capacity range of 15 kW to 350 kW and 2 MW to 10 MW

机译:在15 kW至350 kW和2 MW至10 MW容量范围内确定低NOx燃烧器尺寸的缩放方法

获取原文

摘要

The generation of generally appalicable dimensioning criteria was fo main improtnance at the development of an air-staged burner concept. There, at the combustion of residual fules, large quantities of harmuful nitrogen oxide emissions are produced, owing to the high fuel nitrogen content. For the reduction of the conversion degree of the nitrogen bound in the fuel, the principle of air-staging was used at the burner devleopment. Apart from low CO and soot emissions, the height of the resulting NOx-emission could be reduced by approximately 40 percent by using the developed air-staged burner, in comparison with burners usually available on the market.
机译:普遍适用的尺寸标准的产生主要是在空气分级燃烧器概念的发展中。在那里,由于燃料氮含量高,在燃烧残余烟气时会产生大量有害的氮氧化物排放。为了降低燃料中结合的氮的转化度,在燃烧器装置中采用了空气分级的原理。除了低的CO和烟尘排放外,与市场上通常提供的燃烧器相比,通过使用发达的空气分级燃烧器,可将产生的NOx排放高度降低约40%。