DIRECT VISCOSITY MEASUREMENT AT HIGH TEMPERATURES

机译:高温下的直接粘度测量

获取原文

摘要

The request of a Fluor Daniel Corporation client to measure the process viscosity of a hydrocarbon liquid,such as stripper bottoms, at a base temperature of 210 °F, has influenced the design of a new sampletemperature conditioning system. The intent of the new design is to measure the process viscosity directlyand continuously at constant base temperature of 210 °F. The system response time is specified such as tobe suitable for closed loop control.Fluor Daniel Control System Engineering and Solartrons' experience in the field of viscosity measurementwere utilized to develop the new sample temperature conditioning system for measuring the processviscosity at controlled constant temperature (selected base temperature). The Viscometer was installed in aslip stream where the sample flow rate is flow controlled providing the following:1. Turbulent mixing to provide a homogeneous uniform composition, temperature, and viscosity.and, as a fall back condition:2.As fall back condition, the viscosity measurement of the process stream at the flowing temperature canbe used to calculate the base viscosity (at base temperature) using the "Indirect" referral method, in theevent of temperature control failure. The indirect or referral method is based on ASTM D341-93equations through which the viscometer is configured with in-situ calibration.Following acceptance of the final system design the client, The new sample temperature conditioningsystem was built and tested successfully. The system has passed its Factory Acceptance Tests in 1999.TheFAT ( factory acceptance test ) results of the final design of the sample temperature conditioning systemhave demonstrated the system capability to measure the viscosity of the process stream directly andcontinuously at the selected base temperature 210 °F with accuracy +1 °F, and viscosity accuracy + 1% FS(Full Scale).The system has been installed, commissioned and has passed its Site Acceptance Tests. Thesystem will be fully operational in April 2000.
机译:福禄丹尼尔公司(Fluor Daniel Corporation)客户的要求是测量烃类液体的过程粘度, 例如底部温度为210°F的汽提塔底部影响了新样品的设计 温度调节系统。新设计的目的是直接测量过程粘度 并在210°F的恒定基准温度下连续运行。指定系统响应时间,例如 适用于闭环控制。 Fluor Daniel控制系统工程和Solartrons在粘度测量领域的经验 被用来开发用于测量过程的新型样品温度调节系统 在受控的恒定温度(选定的基准温度)下的粘度。粘度计安装在 样品流受流量控制的滑流,提供以下功能: 1.湍流混合,以提供均匀,均匀的组成,温度和粘度。 并且,作为后备条件: 2.作为回退条件,可以测量流动温度下的过程流的粘度 用于通过“间接”引用方法计算基础粘度(在基础温度下)。 温度控制故障。间接或推荐方法基于ASTM D341-93 粘度计通过现场校准配置的方程式。 客户接受最终系统设计后,新样品温度调节 系统已构建并成功测试。该系统于1999年通过了工厂验收测试。 FAT(工厂验收测试)样品温度调节系统最终设计结果 已经证明了该系统具有直接测量工艺物流粘度的能力,并且 在选定的基础温度210°F下连续测量,精度为+1°F,粘度精度为+ 1%FS (全面):该系统已安装,调试并通过了现场验收测试。这 该系统将于2000年4月全面投入使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号