Inductively coupled plasma-optically emission spectrometry (ICP-OES) has been used to determine the minor and trace elements in iron and steel. However, due to the line-rich Fe matrix and the insufficient detection limits of some trace elements, the analytes are generally preconcentrated and removed from the matrix prior to their determinations. In this work, an optimized axially viewed ICP was used to improve the detection limits of As, Co, Cr, Cu, Mn, Mo, Ni, P, Pb, Ti, Sb and Sn in steel and iron and to eliminate the Fe matrix effect. In addition, the multicomponent spectral fitting (MSF) method was applied to correct the spectral interferences. Satisfactory results were obtained.
机译:电感耦合等离子体发射光谱法(ICP-OES)已用于测定钢铁中的微量元素和痕量元素。但是,由于富含铁的铁基质以及某些痕量元素的检测限不足,因此通常在分析物被确定之前就对其进行了预浓缩和从基质中去除。在这项工作中,使用了优化的轴向观察ICP来提高钢和铁中As,Co,Cr,Cu,Mn,Mo,Ni,P,Pb,Ti,Sb和Sn的检测限并消除Fe基体影响。此外,多组分光谱拟合(MSF)方法被应用于校正光谱干扰。获得满意的结果。