摘要

Little data exisis in the public domain for lithium-ion batteries that have encountered prolonged cycling and operation at high rates and high temperatures.Six UR.18650 lithium-ion cells were continuously charged/discharged at a constant temperature of 50°C at currents of 3.2A. 2.6A or 1.3A charge and discharged at 1.3W to a capacity cutoff of 65mAh. No cells showed any venting, fire or bulging during or after the tests.The amount of hydrogen, was measured by placing chips scraped from the negative electrode in water. The amount of hydrogen from the "as received" and cells after completion of cycling was less than 15 1/kg/hr. However, the amount of hydrogen evolved from the negative electrode of fully charged cells was as high as 87.4 1/kg/hr.Two fully charged cells were subjected to the DoT nail penetration test. No venting, fire or explosion was observed.
机译:对于锂离子电池来说,在高速率和高温下长时间循环和运行时,在公共领域几乎没有数据可言。 六个UR.18650锂离子电池在50°C的恒定温度下以3.2A的电流连续充电/放电。 2.6A或1.3A充电并以1.3W放电至65mAh的容量截止值。在测试期间或之后,没有细胞显示出任何通风,着火或鼓胀的现象。 通过将从负极刮下的碎屑置于水中来测量氢的量。循环完成后,来自“原样”和电池的氢气量少于15 1 / kg / hr。但是,从充满电的电池的负极放出的氢量高达87.4 1 / kg / hr。 将两个充满电的电池进行DoT指甲穿透测试。没有观察到通风,着火或爆炸。