A two-stage 4 K Modified-Solvay cycle cryocooler~1, which is a pneumatically driven Gifford -McMahon cryocooler and will be used for the conduction-cooled low temperature superconducting magnets, has been optimized by numerical and experimental study. After the optimization, the maximum cooling capacity of 36.5 W at 35 K on the first stage and 1.08 W at 4.2 K on the second stage with 6.7 kW input power has been obtained. This is the world's first pneumatically driven G-M cryocooler which has over 1 W cooling capacity at 4.2 K. In this paper, experimental and numerical results of the influence of the valve opening teming and the displacer motion concerning the cooling capacity are described. The experimentally obtained optimum P-V diagram and valve timing are in good agreement with the numerical simulation results. And the reliability tests (over 100 times of cool-down and warm-up cycle, and over 3,000 hours continuous operation) were successfully conducted. It can be expected that this 4 K cryocooler has a high reliability equivalent to the commercial G-M cryocoolers which operate above 10 K on the 2nd stage temperature.
机译:两级4K改装溶剂循环循环〜1,是一种气动驱动的Gifford-Mmahon冷冻室,将用于导电冷却的低温超导磁铁,通过数值和实验研究进行了优化。优化后,在第一阶段35 k的最大冷却能力为36.5W,第二阶段在4.2 k下为1.08W,具有6.7kW输入功率。这是世界上第一个气动驱动的G-M冷冻机,其在4.2K处具有超过1W的冷却能力。在本文中,描述了阀门开度静止的影响和关于冷却能力的置换器运动的实验和数值结果。实验获得的最佳P-V图和阀门正时与数值模拟结果吻合良好。和可靠性测试(超过100次冷却和预热循环,超过3,000小时的连续操作)。可以预期,这4 k冷冻机具有相当于商用G-M冷冻机的高可靠性,其在第二级温度上以高于10 k。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号