Three sample digestion methods have been used as the preparative step prior to analyses by ICP-MS: peroxide fusion (peroxide + carbonate) and microwave digestion by Harwell and wet ashing ('open' acid digestion) and microwave digestion by Imperial College (IC). As one part of the study was aimed at analysing samples from laboratory scale coal gasification equipment, digestions at IC were carried out using a range of sample sizes, at times as small as 10 mg. Since all three digestion techniques appeared to give rise to loss of mercury, a Leco atomic absorption spectrophotometer based method has been used to determine mercury contents.
机译:ICP-MS进行分析之前,已将三种样品消解方法用作制备步骤:过氧化物熔融(过氧化物+碳酸盐),Harwell微波消解,湿灰化(“开放式”酸消解)和帝国理工学院(IC)微波消解。由于该研究的一部分旨在分析实验室规模的煤气化设备中的样品,因此使用各种样品大小(有时小至10 mg)在IC上进行消解。由于所有三种消解技术似乎都导致汞的损失,因此已使用基于Leco原子吸收分光光度计的方法来确定汞含量。