首页> 外文会议>International instrumentation symposium >Measurement errors associated with the transient heating of electrical-resistance strain gages
【24h】

Measurement errors associated with the transient heating of electrical-resistance strain gages

机译:与电阻应变计的瞬时加热相关的测量误差

获取原文

摘要

Significant strain-gage errors may exist in measurements acquired in transient temperature environments if conventional correction methods are applied. Conventional correction theory was modified and a new experimental method was developed to correct indicated straind ata for errors created in radiant heating environments ranging from 0.6 deg C/sec (1 deg F/sec) to over 56 deg C/sec (100 deg F/sec). In some cases the new and conventional methods differed by as much as 30 percent. Experimental and analytical results were compared to demonstrate the new technique. For heating conditions greater than 6 deg C/sec (10 deg C/sec), the indicated strain data corrected with the developed technique compared much better to analysis than the same data corrected with the conventional technique.
机译:如果应用常规校正方法,则在瞬态温度环境下获得的测量结果中可能会存在明显的应变仪误差。修改了传统的校正理论,并开发了一种新的实验方法来校正指示的应变ata,以解决辐射加热环境中从0.6摄氏度/秒(1摄氏度/秒)到超过56摄氏度/秒(100摄氏度/秒)的误差。秒)。在某些情况下,新方法和传统方法相差多达30%。实验和分析结果进行了比较,以证明该新技术。对于大于6摄氏度/秒(10摄氏度/秒)的加热条件,用发达技术校正的指示应变数据比用传统技术校正的相同数据对分析的比较要好得多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有