【24h】

Ballistocardiographic Spectrum Studies with a Tilt Table

机译:带倾斜台的心动描记谱研究

获取原文

摘要

The purpose of this preliminary work is to study the effect of a tilt table test procedure on ballistocardiographic (BCG) signal by using Electromechanical Film (EMFi) sensors. The ECG, BCG, carotid pulse (CP) from the neck near the carotid artery and ankle pulse signals were recorded from 7 persons. The spectral and temporal components of the recordings during the tilt table test were studied.The spectral and temporal properties of BCG signal changed due to the tilt test, change in amplitude levels of the systolic BCG components and in spectral domain. Blood pressure values and pulse changed due to the tilt test. This was also seen in the changed aortic pulse wave velocity (PWV) values. According to this study, BCG measurements combined with a tilt test can be used as a very simple non-invasive method in hemodynamic studies.
机译:这项初步工作的目的是通过使用机电膜(EMFi)传感器研究倾斜台测试程序对心电图(BCG)信号的影响。记录了来自7个人的颈动脉附近颈部的ECG,BCG,颈动脉脉搏(CP)和脚踝脉搏信号。研究了倾斜台测试期间记录的频谱和时间分量。 BCG信号的频谱和时间特性由于倾斜测试,收缩性BCG成分的振幅水平以及频谱域的变化而改变。血压值和脉搏由于倾斜测试而改变。从主动脉脉搏波速度(PWV)值的变化中也可以看出这一点。根据这项研究,BCG测量与倾斜测试相结合可以用作血液动力学研究中非常简单的非侵入性方法。