Dose Distribution Depending on the Number of Control Points in Forward-Planned Intensity-Modulated Radiation Therapy for Breast Cancer

机译:剂量分布取决于乳腺癌前瞻性强度调节放射治疗中控制点的数量

获取原文

摘要

Dose uniformity was estimated depending on the number of control points in forward-planned intensity-modulated radiation therapy for breast cancer.Data were obtained from four patients who had undergone left-sided breast conserving surgery. Five plans for each patient were designed depending on the size of dose clouds to be blocked. To evaluate the effect of the technique on dose uniformity maximum dose, conformity index, and percent volume of the breast more than 95% of the prescription dose were calculated.Although there is no clinical difference between segmented field-in-field technique and control points field-in-field technique, dose distribution in a plan did not depend on the only number of control points, but also depend on the breast size and the shape after the breast surgery. To acquire simple and reasonable monitor units for each control point, minimum 3 MUs are needed.
机译:根据前瞻性乳腺癌强度调制放射治疗中控制点的数量,估计剂量的均匀性。 数据来自四名接受了左侧乳房保留手术的患者。根据要阻止的剂量云的大小,为每个患者设计了五个计划。为了评估该技术对剂量均匀性的最大剂量,一致性指数和大于95%处方剂量的乳房体积百分比的影响,计算得出。 尽管分段场技术和控制点场技术之间在临床上没有区别,但计划中的剂量分布不仅仅取决于控制点的数量,还取决于乳房的大小和形状乳房手术后。为了获得每个控制点简单合理的监控单元,至少需要3个MU。