首页> 外文会议>IEEE Computer Society symposium on research in security and privacy >Analysis of 12 pulse phase control AC/DC converter
【24h】

Analysis of 12 pulse phase control AC/DC converter

机译:12脉冲相位控制交/直流转换器的分析

获取原文

摘要

In this paper, the unbalanced current in the 12-pulse phasecontrol AC/DC converters was studied. The 12-pulse Δ-Y type AC/DCconverter will keep a balanced voltage with 30° phase shifted at thelow coupling coefficient condition, but an unbalanced current will beobtained in the 12-pulse autotransformer phase shift AC/DC converter atthe low coupling coefficient condition. The theoretical phasor analysisof the unbalanced current was presented and a feedback controller wasdesigned to overcome this problem. Finally, a 3 kW 12-pulseautotransformer phase shifted AC/DC converter was implemented todemonstrate the theoretical analysis
机译:本文中的12脉冲相中的不平衡电流 研究了控制AC / DC转换器。 12脉冲Δ-Y型AC / DC 转换器将保持30°相移的平衡电压 低耦合系数条件,但会出现不平衡电流 在12脉冲自耦变压器相移AC / DC转换器中获得 低耦合系数条件。理论相量分析 提出了不平衡电流的变化,反馈控制器是 设计来克服这个问题。最后是一个3 kW的12脉冲 实现了自耦移相AC / DC转换器 证明理论分析

著录项