首页> 外文会议>Conference on ophthalmic technologies >En-face Imaging of the Ellipsoid Zone in the Retina from Optical Coherence Tomography B-scans
【24h】

En-face Imaging of the Ellipsoid Zone in the Retina from Optical Coherence Tomography B-scans

机译:从光学相干断层扫描B扫描的视网膜中椭圆形区的孔面成像

获取原文

摘要

It is generally believed that photoreceptor integrity is related to the ellipsoid zone appearance in optical coherence tomography (OCT) B-scans. Algorithms and software were developed for viewing and analyzing the ellipsoid zone. The software performs the following: (a), automated ellipsoid zone isolation in the B-scans, (b), en-face view of the ellipsoid-zone reflectance, (c), alignment and overlay of (b) onto reflectance images of the retina, and (d), alignment and overlay of (c) with microperimetry sensitivity points. Dataset groups were compared from normal and dry age related macular degeneration (DAMD) subjects. Scalar measurements for correlation against condition included the mean and standard deviation of the ellipsoid zone's reflectance. The image-processing techniques for automatically finding the ellipsoid zone are based upon a calculation of optical flow which tracks the edges of laminated structures across an image. Statistical significance was shown in T-tests of these measurements with the population pools separated as normal and DAMD subjects. A display of en-face ellipsoid-zone reflectance shows a clear and recognizable difference between any of the normal and DAMD subjects in that they show generally uniform and nonuniform reflectance, respectively, over the region near the macula. Regions surrounding points of low microperimetry (uP) sensitivity have nonregular and lower levels of ellipsoid-zone reflectance nearby. These findings support the idea that the photoreceptor integrity could be affecting both the ellipsoid-zone reflectance and the sensitivity measurements.
机译:通常认为光感受器完整性与光学相干断层扫描(OCT)B扫描中的椭圆形区域外观有关。开发了用于查看和分析椭球区域的算法和软件。该软件执行以下内容:(a),B扫描中的自动椭球区域隔离,(b),椭圆区反射率的雕刻视图,(c),(b)的对准和覆盖物到反射图像的反射图像上视网膜和(d),(c)的对准和覆盖,具有微型敏感点。将数据集组与正常和干燥的年龄相关的黄斑变性(DAMD)受试者进行比较。禁止条件相关的标量测量包括椭圆形区的均值和标准偏差。用于自动找到椭圆形区域的图像处理技术基于光流量的计算,该光流追踪图像跨图像的层叠结构的边缘。在这些测量的T检验中显示统计学显着性,与正常和DAMD受试者分开的人口库。 En-Face椭圆区反射率的显示屏显示了任何正常和DAMD受试者之间的清晰可识别的差异,因为它们分别在黄斑附近的区域上显示出通常均匀和不均匀的反射率。围绕微量微孔(上)敏感性的地区具有非公差和较低水平的椭圆区反射。这些发现支持了感光体完整性可能影响椭球区域反射率和敏感性测量的想法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号