首页> 外文会议>IEEE International Symposium on Electrical Insulation >Comparative AC VET on new bars and on bars previously subjected to DC VET
【24h】

Comparative AC VET on new bars and on bars previously subjected to DC VET

机译:在新杆上的比较AC VET和以前对DC VET进行的酒吧

获取原文

摘要

A previous experiment was performed to compare the aging effect of AC and DC high-voltage on the groundwall insulation of 13.8 kV Roebel bars [1]. For this purpose, Voltage Endurance Test (VET) was performed on twelve spare bars. Half of the test specimens were submitted to a voltage of 35 kVac, and failures occurred on all bars in less than 150 hours. For this experiment, a ratio of 1.7 between direct voltage and power frequency voltage (RMS) was used. The other half of the test specimens were then tested at a voltage of 59.5 kVdc. Further in this experiment, since none of the bars subjected to the DC VET had failed during a test period of more than 2000 hours, it was decided to perform an AC voltage endurance test on these bars. This paper presents the test results of a comparative AC voltage endurance test performed on new bars and on bars previously subjected to a long term DC VET.
机译:进行了先前的实验以比较AC和DC高压对13.8kV罗布尔棒的地下隔热的老化效果[1]。为此目的,在十二个备件上进行电压耐久性测试(VET)。一半的测试标本的提交到35kVAC的电压,并且在少于150小时的所有条形中发生故障。对于该实验,使用直接电压和功率频率电压(RMS)之间的比率为1.7。然后在59.5kVdc的电压下测试测试样品的另一半。此外,在该实验中,由于在2000小时的测试期间进行DC VET的条形没有失败,因此决定在这些杆上进行交流电压耐久性测试。本文介绍了在新杆和先前经过长期DC VET的条上进行的比较交流电压耐久性试验的测试结果。