首页> 外文会议>Electrical Insulation (ISEI), Conference Record of the 2012 IEEE International Symposium on >Comparative AC VET on new bars and on bars previously subjected to DC VET
【24h】

Comparative AC VET on new bars and on bars previously subjected to DC VET

机译:新条和先前已经受DC VET的条上的比较AC VET

获取原文
获取原文并翻译 | 示例

摘要

A previous experiment was performed to compare the aging effect of AC and DC high-voltage on the groundwall insulation of 13.8 kV Roebel bars [1]. For this purpose, Voltage Endurance Test (VET) was performed on twelve spare bars. Half of the test specimens were submitted to a voltage of 35 kVac, and failures occurred on all bars in less than 150 hours. For this experiment, a ratio of 1.7 between direct voltage and power frequency voltage (RMS) was used. The other half of the test specimens were then tested at a voltage of 59.5 kVdc. Further in this experiment, since none of the bars subjected to the DC VET had failed during a test period of more than 2000 hours, it was decided to perform an AC voltage endurance test on these bars. This paper presents the test results of a comparative AC voltage endurance test performed on new bars and on bars previously subjected to a long term DC VET.
机译:进行了先前的实验,以比较交流和直流高压对13.8 kV Roebel棒的接地绝缘的老化影响[1]。为此,对十二个备用条进行了耐压测试(VET)。一半的试样承受了35 kVac的电压,并且在不到150小时的时间内所有试条都发生了故障。对于此实验,使用直流电压与工频电压(RMS)之比为1.7。然后在59.5 kVdc的电压下测试另一半试样。此外,在该实验中,由于经受DC VET的所有试条都没有在超过2000小时的测试时间内失败,因此决定对这些试条进行AC耐压测试。本文介绍了在新的试条和先前经受长期DC VET的试条上进行的比较AC耐压测试的测试结果。