摘要

Following the very successful application of extruded polyethylene insulation to coaxial submarine telephone cables, the first high voltage power transmission circuit using this insulation under water was energized in 1968 at Cook Inlet, Alaska. The accumulated experience with 138 kV solid dielectric submarine cables now amounts to nearly 30 circuit-mile-years without a single electrical underwater fault. The major advantages of this new form of cable are simplicity in construction, easier installation, and lower electrical capacitance and thermal impedance. The critical length of a 138 KV cable with 2000 MCM conductor is 150-200 miles, depending on sediment thermal resistivity. Extruded polyethylene insulation, therefore, makes it possible to transmit ac power over long distances under water.
机译:在将挤出聚乙烯绝缘材料成功应用于水下海底同轴电缆之后,1968年在阿拉斯加的库克莱特(Cook Inlet)为第一套使用这种绝缘材料的水下高压输电线路通电。如今,138 kV固体绝缘海底电缆的累积经验已达到近30电路英里-年,而没有任何水下电气故障。这种新型电缆的主要优点是结构简单,易于安装以及较低的电容和热阻。具有2000 MCM导体的138 ​​KV电缆的临界长度为150-200英里,具体取决于沉积物的热阻率。因此,挤出的聚乙烯绝缘材料可以在水下长距离传输交流电。