首页> 外文会议> >Further study on in-situ measurement of complex EM parameters with a flanged open-ended coaxial probe
【24h】

Further study on in-situ measurement of complex EM parameters with a flanged open-ended coaxial probe

机译:带法兰的开放式同轴探头现场测量复杂电磁参数的进一步研究

获取原文

摘要

A measurement system based on open-ended coaxial probe technique is set up to characterize the EM properties of radar-absorbing material situ. Frequency-varying method (FVM), which simultaneously extracts complex EM-parameters, i.e. /spl epsiv/ and /spl mu/, by intentionally varying the test frequency to obtain two different reflections, is further studied with an emphasis on several key techniques. Criterions for a right order of the interpolation polynomial used to approximate the frequency-dependent EM-parameters; measures to reduce the residual mismatch errors in reflection measurements and to suppress the ambiguities in solving the transcendent equation system are discussed in detail. Several typical radar-absorbing coatings are measured via FVM and the good results validate the feasibility of this in-situ measurement technique.
机译:建立了基于开放式同轴探针技术的测量系统,以现场表征雷达吸收材料的电磁特性。通过有意地改变测试频率以获得两个不同的反射,同时研究了同时提取复杂的EM参数(即/ spl epsiv /和/ spl mu /)的频率变化方法(FVM),重点研究了几种关键技术。插值多项式的右阶判据,用于近似于频率相关的EM参数;详细讨论了减少反射测量中的残余失配误差并抑制求解超越方程组时的歧义的措施。通过FVM测量了几种典型的雷达吸收涂层,良好的结果证明了这种现场测量技术的可行性。