In order to determine the size of myocardial perfusion infarcts in clinical SPECT images, we have developed a software package iQuant that eliminates the need for a normal-heart database - a problem that exists in commercial products. Details of the iQuant method are presented in this paper together with results from preliminary tests of accuracy and reproducibility. iQuant uses different count thresholds to define viable myocardial tissue and to provide a rough outline of the complete myocardium. This outline together with the visible thickness of the viable myocardium is used by the operator as a guide to determine the location and size of infarcted tissue. Using noiseless data iQuant is shown to be accurate to within 5%; with more clinically realistic simulated data the measured accuracy is 14%. When testing reproducibility, independent operators consistently produced results within 10% of the truth. Clinical experience was shown to be an important factor in the reproducible accuracy of each individual observer. Measurements to date only involve infarcts considered clinically small, but further work is planned to investigate the reliability of this method over a large range of infarct sizes and locations. Initial analysis shows the iQuant software to be an objective, robust and versatile tool suitable for the determination of myocardial perfusion infarct size in the clinical research environment. Its elimination of the need for a normal-heart database is its main advantages over current, commercially availably software.
机译:为了确定临床SPECT图像中的心肌梗塞的大小,我们开发了iQuant软件包,消除了对正常心脏数据库的需求-这是商业产品中存在的问题。本文介绍了iQuant方法的详细信息以及准确性和可重复性的初步测试结果。 iQuant使用不同的计数阈值来定义可行的心肌组织并提供完整心肌的粗略轮廓。该轮廓与活心肌的可见厚度一起被操作者用作确定梗塞组织的位置和大小的指南。使用无噪声数据,iQuant的准确度显示在5%以内。使用更符合临床实际的模拟数据,测量的准确性为14%。在测试可重复性时,独立的操作员会始终在真相的10%范围内产生结果。事实证明,临床经验是影响每个观察者可重复性准确性的重要因素。迄今为止的测量仅涉及临床上认为较小的梗塞,但计划进行进一步的工作以研究该方法在大范围的梗塞范围和位置上的可靠性。初步分析表明,iQuant软件是一种客观,可靠,多功能的工具,适用于确定临床研究环境中的心肌灌注梗死面积。与目前的市售软件相比,它消除了对正常心脏数据库的需求是其主要优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号