A novel bench-top device for producing intense, fast pulses of X-rays has been designed with 10 ps fwhm (full-width at half-maximum) X-ray pulse width, 120 keV maximum energy, 100 kHz repetition rate, and 1 A peak current onto the X-ray anode. The device includes three sections: (1) an electron gun that generates 5 ns wide pulses of 120 keV electrons at 100 kHz; (2) solenoidal magnetic lenses and deflection plates that focus the electrons onto an aperture plate and sweep the pulsed beam past the aperture, respectively; and (3) a tungsten anode onto which the post-aperture electrons are focused, producing pulses of X-rays. Using solenoidal magnetic lenses with a current density of 150 A/spl middot/turns/cm/sup 2/ to focus the electron beam, a deflection plate dV/dt of 10/sup 13/ V/s is needed to achieve electron pulse widths of about 10 ps. The design process used EGUN (an electron optics and gun design program) electron trajectory simulations, including calculation of important space charge effects. When built, this instrument will be used to excite scintillator samples in crystal or powdered form, allowing fluorescent lifetimes and spectra to be measured with a microchannel PMT. The very narrow 10 ps X-ray pulse width is necessary for accurate measurements of the risetimes of very fast scintillators (e.g., BaF/sub 2/). In addition, the large X-ray flux (1 A peak current) is advantageous when using a reflection grating monochromator to measure decay times at different wavelengths.
机译:一种用于产生强烈的X射线的新型台式设备,设计有10 PS FWHM(半最大宽度)X射线脉冲宽度,120keV最大能量,100 kHz重复率和1 X射线阳极上的峰值电流。该装置包括三个部分:(1)在100kHz处产生120keV电子的5 ns宽脉冲的电子枪; (2)电磁磁透镜和偏转板,将电子聚焦到孔板上并分别扫过孔径的脉冲梁; (3)将孔径电子的聚焦,产生X射线的脉冲的钨阳极。使用具有电流密度为150A / SPL中间/匝/匝/匝/匝/匝/匝/匝/匝/匝/匝的电磁磁性透镜/聚焦电子束,需要10 / SUP 13 / s的偏转板DV / DT以实现电子脉冲宽度约10 ps。设计过程使用egun(电子光学和枪设计程序)电子轨迹模拟,包括计算重要空间电荷效应。在构建时,该仪器将用于激发晶体或粉末形式的闪烁体样品,允许用微通道PMT测量荧光寿命和光谱。非常窄的10ps X射线脉冲宽度是精确测量非常快速的闪烁体(例如,BAF / SUB 2 /)的准确测量所必需的。另外,当使用反射光栅单色器以测量不同波长的衰减时间时,大的X射线通量(1 a峰值电流)是有利的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号