Neutron dose equivalent rates have been measured for 800-MeV proton beam spills at the Los Alamos Meson Physics Facility. Neutron detectors were used to measure the neutron dose levels at a number of locations for each beam-spill test, and neutron energy spectra were measured for several beam-spill tests. Estimates of expected levels for various detector locations were made using a simple analytical model developed for 800-MeV proton beam spills. A comparison of measurements and model estimates indicates that the model is reasonably accurate in estimating the neutron dose equivalent rate for simple shielding geometries. The model fails for more complicated shielding geometries, where indirect contributions to the dose equivalent rate can dominate.
机译:在Los Alamos Meson物理设施测量了800 MeV质子束溢出的中子剂量当量率。对于每个电子束泄漏测试,使用中子探测器在多个位置测量中子剂量水平,并针对多个电子束泄漏测试测量中子能谱。使用针对800 MeV质子束溢出而开发的简单分析模型,可以估算出各种探测器位置的预期水平。测量值与模型估计值的比较表明,对于简单的屏蔽几何形状,模型在估计中子剂量当量率方面相当准确。该模型无法用于更复杂的屏蔽几何形状,其中对剂量当量率的间接影响可能占主导地位。