Abstract: Irreversible data compression methods have been proposed to reduce the data storage and communication requirements of digital imaging systems. In general, the error produced by compression increases as an algorithm's compression ratio is increased. We have studied the relationship between compression ratios and the detection of induced error using radiologic observers. The nature of the errors was characterized by calculating the power spectrum of the difference image. In contrast with studies designed to test whether detected errors alter diagnostic decisions, this study was designed to test whether observers could detect the induced error. A paired-film observer study was designed to test whether induced errors were detected. The study was conducted with chest radiographs selected and ranked for subtle evidence of interstitial disease, pulmonary nodules, or pneumothoraces. Images were digitized at 86 microns (4K $MUL 5K) and 2K $MUL 2K regions were extracted. A full-frame discrete cosine transform method was used to compress images at ratios varying between 6:1 and 60:1. The decompressed images were reprinted next to the original images in a randomized order with a laser film printer. The use of a film digitizer and a film printer which can reproduce all of the contrast and detail in the original radiograph makes the results of this study insensitive to instrument performance and primarily dependent on radiographic image quality. The results of this study define conditions for which errors associated with irreversible compression cannot be detected by radiologic observers. The results indicate that an observer can detect the errors introduced by this compression algorithm for compression ratios of 10:1 (1.2 bits/pixel) or higher. !
机译:摘要:已经提出了不可逆的数据压缩方法,以减少数字成像系统的数据存储和通信需求。通常,压缩产生的误差随着算法压缩率的增加而增加。我们研究了压缩比与使用放射学观察者检测诱发错误之间的关系。通过计算差异图像的功率谱来表征错误的性质。与旨在测试检测到的错误是否会改变诊断决策的研究相反,本研究旨在测试观察者是否能够检测到导致的错误。配对电影观察者研究旨在测试是否检测到诱发的错误。这项研究是通过选择胸部X光片进行的,并对其排序以发现间质疾病,肺结节或气胸的微妙证据。在86微米处将图像数字化(4K $ MUL 5K),并提取2K $ MUL 2K区域。使用全帧离散余弦变换方法以6:1和60:1之间的比率压缩图像。用激光胶片打印机以随机顺序将解压缩后的图像重新打印在原始图像旁。胶片数字化仪和胶片打印机的使用可以再现原始射线照片中的所有对比度和细节,因此这项研究的结果对仪器性能不敏感,并且主要取决于射线照相的图像质量。这项研究的结果定义了放射观察者无法检测到与不可逆压缩有关的错误的条件。结果表明,对于10:1(1.2位/像素)或更高的压缩率,观察者可以检测到此压缩算法引入的错误。 !

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号