This paper has investigated the failure of a vertical heat exchanger used in processingrnboiler feed water. The bundle of the heat exchanger was removed from service after 8 years forrnmetallurgical investigation. The tube side contains boiler feed water at 622°F and 1800 psig; thernprocess gas heats the shell at 1836oF and 565psia.rnThe tubes failed to provide expected performance due to restriction caused by thernpresence of tightly adhered deposits on the internal surface of the tube. The samples exhibitedrnextensive coverage of iron oxide deposits (hematite, Fe_2O_3 and magnetite, Fe_3O_4).rnMicrostructures on the outer surface of the tubes were more homogenized when compared to thernmicrostructures on the internal surface which contains predominantly segregated and bandedrnstructures. Both microstructure variation on the tube surfaces and the nature of the deposits couldrnhave severely influenced the general performance of the tubes of the heat exchanger.
机译:本文研究了用于锅炉给水的立式换热器的故障。在进行了8年的冶金学研究后,该热交换器束已停止使用。管侧装有622°F和1800 psig的锅炉给水;工艺气体在1836oF和565psia下加热外壳。由于管内表面上紧密附着的沉积物所造成的限制,管未能提供预期的性能。样品表现出广泛的氧化铁沉积物覆盖(赤铁矿,Fe_2O_3和磁铁矿,Fe_3O_4)。与内表面主要包含偏析和带状结构的显微组织相比,管外表面的显微组织更为均质。管表面的微观结构变化和沉积物的性质都可能严重影响热交换器管的总体性能。