首页> 外文期刊>Case Studies in Engineering Failure Analysis >Failure analysis of tube-to-tubesheet welded joints in a shell-tube heat exchanger
【24h】

Failure analysis of tube-to-tubesheet welded joints in a shell-tube heat exchanger

机译:管壳式换热器中管对管板焊接接头的失效分析

获取原文
       

摘要

Failure analysis was carried out on a tube-to-tubesheet welded joint of a shell-tube heat exchanger to confirm its failure mechanism. The collected evidence suggests that the failure of the tube-to-tubesheet welded joint was induced by fatigue. Under the morphology analysis, the fracture surface exhibit obvious fatigue crack propagation traces. Fatigue striations were observed clearly in the propagation zone. Detecting results showed that chemical composition and mechanical properties of the tubes was consistent with the standard requirements for the 304 stainless steel. The metallographic test showed that the microstructure of both the tube and tubesheet were normal. However, serious defects were found at the tube-to-tubesheet welded joint. The fatigue crack initiated from the defects at the tube-to-tubesheet welded joint. The periodic load might come from the resonant vibration of the tube or the changes in temperature and pressure of the fluid inside the heat exchanger. Bad welding and unsuitable expansion position of the tubes at the tube-to-tubesheet might give rise to the formation of initial cracks.
机译:对壳管式热交换器的管对管板焊接接头进行了故障分析,以确认其故障机理。收集的证据表明,管对管板焊接接头的失效是由疲劳引起的。经形态分析,断口表面表现出明显的疲劳裂纹扩展痕迹。在繁殖区清楚地观察到疲劳条纹。检测结果表明,该管的化学成分和力学性能符合304不锈钢的标准要求。金相测试表明,试管和管板的显微组织均正常。然而,在管对管板的焊接接头处发现了严重的缺陷。疲劳裂纹是由管对管板焊接接头处的缺陷引起的。周期性负载可能来自管子的共振振动,也可能来自热交换器内部流体温度和压力的变化。管对管板上的不良焊接和管的不合适的膨胀位置可能会引起初始裂纹的形成。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号